- Electric field measurement
- Isotropic & True RMS measurement
- Excellent attenuation at 50/60 Hz
- Measurements in accordance with International Standards
Discover the possibilities
More information
Description
Main Applications
- Telecommunications
- Wireless telecom networks: IEC 62232, EN 50400, EN 50401
- Broadcast: IEC 6251237, EN 50475, EN 50476, EN 50496, EN 50554
- Satellite installations
- Workplace assessment: EN 50499
- Assessment of workers bearing AIMDs: EN 50527-1
- Human exposure assessment: EN 50413
- Research/Labs
- Microwave drying
- Detection of leaks
- Radar
- Defense (HF)
Specifications
- Frequency range: 30 MHz - 90 GHz
- Sensor type: Isotropic RMS diode technology
- Type of frequency response: Flat
- Measurement range: 1.2 – 1000 V/m (CW), 1.2 – 70 V/m (RMS)
- Dynamic range: 58 dB
- Sensitivity: 1.2 V/m
- Frequency response:
- ± 3 dB (30 MHz – 50 GHz)
- ± 1/-6 dB (50 GHz – 60 GHz)
- 0/-10 dB (60 GHz – 90 GHz)
- Linearity: ± 1 dB (2 – 250 V/m)
- Isotropic deviation:
- ± 1 dB (< 12 GHz)
- ± 2 dB (12 GHz to 60 GHz)
- ± 3.5 dB (60 GHz to 90 GHz)
- Damage level (CW): 1200 V/m
- Calibration: ISO 17025 Accredited Calibration (ILAC)
- Calibration period: 24 months (recommended)
- Temperature range: - 20 ºC to 50 ºC
- Temperature response: + 0.1 / - 1 dB (related to 20 ºC)
- Dimensions: 28.4 cm x 6 cm Ø
- Weight: 95 g
- Attenuation at 50/60 Hz: > 40 dB
Documents
Datasheet:
Options
Video
Main Applications
- Telecommunications
- Wireless telecom networks: IEC 62232, EN 50400, EN 50401
- Broadcast: IEC 6251237, EN 50475, EN 50476, EN 50496, EN 50554
- Satellite installations
- Workplace assessment: EN 50499
- Assessment of workers bearing AIMDs: EN 50527-1
- Human exposure assessment: EN 50413
- Research/Labs
- Microwave drying
- Detection of leaks
- Radar
- Defense (HF)
- Frequency range: 30 MHz - 90 GHz
- Sensor type: Isotropic RMS diode technology
- Type of frequency response: Flat
- Measurement range: 1.2 – 1000 V/m (CW), 1.2 – 70 V/m (RMS)
- Dynamic range: 58 dB
- Sensitivity: 1.2 V/m
- Frequency response:
- ± 3 dB (30 MHz – 50 GHz)
- ± 1/-6 dB (50 GHz – 60 GHz)
- 0/-10 dB (60 GHz – 90 GHz)
- Linearity: ± 1 dB (2 – 250 V/m)
- Isotropic deviation:
- ± 1 dB (< 12 GHz)
- ± 2 dB (12 GHz to 60 GHz)
- ± 3.5 dB (60 GHz to 90 GHz)
- Damage level (CW): 1200 V/m
- Calibration: ISO 17025 Accredited Calibration (ILAC)
- Calibration period: 24 months (recommended)
- Temperature range: - 20 ºC to 50 ºC
- Temperature response: + 0.1 / - 1 dB (related to 20 ºC)
- Dimensions: 28.4 cm x 6 cm Ø
- Weight: 95 g
- Attenuation at 50/60 Hz: > 40 dB