TESEQ GTEM 250 Cell for Emissions and Immunity Testing
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
- Emissions and immunity testing in a single, shielded environment
- Meets basic standard: IEC/EN 61000-4-20
- Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
- Meets standards for immunity testing: EN 60118-13
- Ideal for design qualification and pre-certification
Discover the possibilities
More information
Description
TESEQ GTEM 250 Cell for Emissions and Immunity Testing
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 250 has a maximum septum height of 250 mm and is suitable for emissions and immunity testing.
Parameter | Value |
---|---|
Max. septum height | 250 mm |
Septum height at marker position | 217 mm |
Dimension (LxWxH) | 1.25 x 0.65 x 0.45 m |
Weight | 45 kg |
Documents
Options
Video
TESEQ GTEM 250 Cell for Emissions and Immunity Testing
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 250 has a maximum septum height of 250 mm and is suitable for emissions and immunity testing.
Parameter | Value |
---|---|
Max. septum height | 250 mm |
Septum height at marker position | 217 mm |
Dimension (LxWxH) | 1.25 x 0.65 x 0.45 m |
Weight | 45 kg |