TESEQ GTEM 1750-Series cells for Emissions and Immunity Testing
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
- Emissions and immunity testing in a single, shielded environment
- Meets basic standard: IEC/EN 61000-4-20
- Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
- Meets standards for immunity testing: EN 60118-13
- Ideal for design qualification and pre-certification
Discover the possibilities
More information
Description
TESEQ GTEM 1750-Series cells for Emissions and Immunity Testing
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 1750 has a maximum septum height of 1750 mm and is suitable for emissions and immunity testing.
Parameter | Value |
---|---|
Max. septum height | 1750 mm |
Septum height at marker position | 1516 mm |
Dimension (LxWxH) | 7.95 x 4.10 x 2.90 m(H in relation to the selected support) |
Weight | approx. 1800 kg |
Height H1 of cell corpus | 2.75 m |
Documents
TESEQ GTEM 1750-Series cells for Emissions and Immunity Testing
GTEM_1750 data sheet GTEM_Cells brochureOptions
TESEQ GTEM 1750-Series cells for Emissions and Immunity Testing
GTEM 1750 GTEM 1750-MPC GTEM 1750-MPHVideo
TESEQ GTEM 1750-Series cells for Emissions and Immunity Testing
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 1750 has a maximum septum height of 1750 mm and is suitable for emissions and immunity testing.
Parameter | Value |
---|---|
Max. septum height | 1750 mm |
Septum height at marker position | 1516 mm |
Dimension (LxWxH) | 7.95 x 4.10 x 2.90 m(H in relation to the selected support) |
Weight | approx. 1800 kg |
Height H1 of cell corpus | 2.75 m |