imc UPS-NiMH Battery Buffed UPS for ARGUSfit
Use our chat for technical support or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
- Battery buffered UPS for imc ARGUSfit (ARGFT) and imc CANSASfit (CANFT)
- Buffering of an entire system of imc ARGUSfit / imc CANSASfit
- Total power approx. 50 W (expected total power of typical configurations)
- Sufficient buffer capacity even under derating conditions (esp. -20°C and moderate aging)
- Fixed delay / buffer time constant of 30 sec. (typical application vehicle start-up process)
- Robust NiMH battery technology
- Additional AUX output for external components
Discover the possibilities
More information
Description
The imc ARGUSfit UPS module is used to bridge short-term power failures that typically occur in vehicle electrical systems. Typical applications are mobile measurement tasks in vehicles where the starting process or start-stop automatics in operation are to be recorded by an uninterrupted measurement. The module is equipped with NiMH batteries. These have a sufficient capacity for several such events, lasting max. 30 s each. If a single power failure exceeds the duration of 30 s, an auto-shutdown of the system is triggered.
Additional output supply sockets "POWER OUT" enable the supply of further external imc devices or modules or blocks (independent of the clicked modules).
Highlights
- Buffering of an entire system of imc ARGUSfit / imc CANSASfit
- Total power approx. 50 W (expected total power of typical configurations)
- Sufficient buffer capacity even under derating conditions (esp. -20°C and moderate aging)
- Fixed delay / buffer time constant of 30 sec. (typical application vehicle start-up process)
- Robust NiMH battery technology
- Additional AUX output for external components
imc ARGUSfit: Flexible modular platform for fast measurement systems
Based on an imc ARGUSfit base unit, imc ARGUSfit measurement amplifier and interface modules can be combined to form complete systems by means of a robust click mechanism, which can even integrate
imc CANSASfit modules. The click connectors provide the electrical connection to the power supply and system bus.
For expansion to decentralized distributed topologies, the fast internal ARGFT system bus can be converted to fiber optic cables by means of a clickable fiber converter module.
The entire system can be controlled via a common Ethernet connection (LAN/WLAN) with a PC (imc STUDIO software) and can be networked and operated synchronously and uniformly with all other imc data acquisition instrument series. Furthermore, it can also be operated autonomously and stand-alone without PC with data storage on microSD.
Specifications
Documents
Options
Video
The imc ARGUSfit UPS module is used to bridge short-term power failures that typically occur in vehicle electrical systems. Typical applications are mobile measurement tasks in vehicles where the starting process or start-stop automatics in operation are to be recorded by an uninterrupted measurement. The module is equipped with NiMH batteries. These have a sufficient capacity for several such events, lasting max. 30 s each. If a single power failure exceeds the duration of 30 s, an auto-shutdown of the system is triggered.
Additional output supply sockets "POWER OUT" enable the supply of further external imc devices or modules or blocks (independent of the clicked modules).
Highlights
- Buffering of an entire system of imc ARGUSfit / imc CANSASfit
- Total power approx. 50 W (expected total power of typical configurations)
- Sufficient buffer capacity even under derating conditions (esp. -20°C and moderate aging)
- Fixed delay / buffer time constant of 30 sec. (typical application vehicle start-up process)
- Robust NiMH battery technology
- Additional AUX output for external components
imc ARGUSfit: Flexible modular platform for fast measurement systems
Based on an imc ARGUSfit base unit, imc ARGUSfit measurement amplifier and interface modules can be combined to form complete systems by means of a robust click mechanism, which can even integrate
imc CANSASfit modules. The click connectors provide the electrical connection to the power supply and system bus.
For expansion to decentralized distributed topologies, the fast internal ARGFT system bus can be converted to fiber optic cables by means of a clickable fiber converter module.
The entire system can be controlled via a common Ethernet connection (LAN/WLAN) with a PC (imc STUDIO software) and can be networked and operated synchronously and uniformly with all other imc data acquisition instrument series. Furthermore, it can also be operated autonomously and stand-alone without PC with data storage on microSD.