Hioki MR8827 Memory HiCorder
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
High-speed 20MS/s 32-channel Fully-isolated Memory Recorder Provides Simultaneous Data Acquisition Over 32 Analog + 32 Logic Channels
Discover the possibilities
More information
Description
Hioki MR8827 Memory HiCorder
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the MR8827 data acquisition (DAQ) recorder accommodates plug-and-play input modules to meet applications such as trial runs after the scheduled maintenance of railway cars to verify for voltage command signals, motor current, car speed, and brake pressure.
Key Features
• Generate and record waveforms with a single unit
• Output previously recorded problematic waveforms and apply to devices under test to simulate potential issues
• 32 analog + 32 logic channels to 28 analog + 64 logic channels • High-speed sampling up to 20MS/s with fully isolated inputs
• Safe measurement with all isolated analog inputs
• Large capacity memory of total 512M-words
• Measure various system signals from high voltage to ultra low voltage simultaneously
Max. Number of channels | 32 ch analog + 32 ch logic, or 28 ch analog + 64 ch logic (when use with built-in logic input + plug-in logic unit 8973 × 2) |
---|---|
Number of slots | 16 slots (Max. 16) |
Number of logic channels | 32 ch logic (logic probe terminal GND share a common GND with chassis) Built-in logic input not available when using DVM Unit MR8990 on slots 1, 2, 9, or 10.[Limitation on using built-in logic input] (with logic measurement ON)• Measurement resolution on slots 1, 2, 9, and slot 10 is limited up to 12 bits• Cannot use Frequency Unit 8970 on slots 1, 2, 9, or 10 |
Measurement ranges (20 div full-scale) | [Analog Unit 8966]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/100 of range (using 12-bit A/D)[High Resolution Unit 8968]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/1600 of range (using 16-bit A/D) |
Max. allowable input | 400 V DC (using the 8966/8968) |
Frequency characteristics | DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968) |
Time axis (Memory function) | 5 µs to 5 min/div, 26 ranges, at 100 points/div resolution |
Measurement functions | Memory (high-speed recording), Recorder (real-time recording), X-Y recorder, FFT |
Other functions | Numerical calculation, Waveform processing, Waveform judgment (at Memory, or FFT function) |
Memory capacity | 128M-words/ch (using 4 Analog channels) to 16M-words/ch (using 32 Analog channels), Total capacity 512MW memory |
Data storage media | USB memory stick, CF card, Built-in SSD unit (option, 128GB) *Approx. 125 sec. when saving 100 MB of data*Data of 100 MB in size can record 16,000 div waveforms across 32 channels. |
Printing | [Built-in A4-size printer option]: 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s |
Display | 10.4 inch TFT color LCD (SVGA, 800 × 600 dots) |
External interfaces | LAN: 100BASE-TX, USB 2.0 series A receptacle 2 port (for USB memory, mouse)USB 2.0 series B receptacle (for communication with PC, mass storage) |
Power supply | 100 to 240 V AC, 50/60 Hz (220 VA max., when using printer: 350 VA max.) |
Dimensions and mass | 401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D (including protruding parts except handle), 12.6 kg (444.4 oz) (main unit only) |
Accessories | Instruction manual ×1, Power cord ×1, Application disk (CD-R) ×1, Input cord label ×1, Printer paper ×1 (when ordering printer unit), Roll paper attachment ×2 (when ordering printer unit) |
Documents
Hioki MR8827 Memory HiCorder
Hioki MR8827 Memory HiCorder datasheetOptions
Video
Hioki MR8827 Memory HiCorder
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the MR8827 data acquisition (DAQ) recorder accommodates plug-and-play input modules to meet applications such as trial runs after the scheduled maintenance of railway cars to verify for voltage command signals, motor current, car speed, and brake pressure.
Key Features
• Generate and record waveforms with a single unit
• Output previously recorded problematic waveforms and apply to devices under test to simulate potential issues
• 32 analog + 32 logic channels to 28 analog + 64 logic channels • High-speed sampling up to 20MS/s with fully isolated inputs
• Safe measurement with all isolated analog inputs
• Large capacity memory of total 512M-words
• Measure various system signals from high voltage to ultra low voltage simultaneously
Max. Number of channels | 32 ch analog + 32 ch logic, or 28 ch analog + 64 ch logic (when use with built-in logic input + plug-in logic unit 8973 × 2) |
---|---|
Number of slots | 16 slots (Max. 16) |
Number of logic channels | 32 ch logic (logic probe terminal GND share a common GND with chassis) Built-in logic input not available when using DVM Unit MR8990 on slots 1, 2, 9, or 10.[Limitation on using built-in logic input] (with logic measurement ON)• Measurement resolution on slots 1, 2, 9, and slot 10 is limited up to 12 bits• Cannot use Frequency Unit 8970 on slots 1, 2, 9, or 10 |
Measurement ranges (20 div full-scale) | [Analog Unit 8966]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/100 of range (using 12-bit A/D)[High Resolution Unit 8968]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/1600 of range (using 16-bit A/D) |
Max. allowable input | 400 V DC (using the 8966/8968) |
Frequency characteristics | DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968) |
Time axis (Memory function) | 5 µs to 5 min/div, 26 ranges, at 100 points/div resolution |
Measurement functions | Memory (high-speed recording), Recorder (real-time recording), X-Y recorder, FFT |
Other functions | Numerical calculation, Waveform processing, Waveform judgment (at Memory, or FFT function) |
Memory capacity | 128M-words/ch (using 4 Analog channels) to 16M-words/ch (using 32 Analog channels), Total capacity 512MW memory |
Data storage media | USB memory stick, CF card, Built-in SSD unit (option, 128GB) *Approx. 125 sec. when saving 100 MB of data*Data of 100 MB in size can record 16,000 div waveforms across 32 channels. |
Printing | [Built-in A4-size printer option]: 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s |
Display | 10.4 inch TFT color LCD (SVGA, 800 × 600 dots) |
External interfaces | LAN: 100BASE-TX, USB 2.0 series A receptacle 2 port (for USB memory, mouse)USB 2.0 series B receptacle (for communication with PC, mass storage) |
Power supply | 100 to 240 V AC, 50/60 Hz (220 VA max., when using printer: 350 VA max.) |
Dimensions and mass | 401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D (including protruding parts except handle), 12.6 kg (444.4 oz) (main unit only) |
Accessories | Instruction manual ×1, Power cord ×1, Application disk (CD-R) ×1, Input cord label ×1, Printer paper ×1 (when ordering printer unit), Roll paper attachment ×2 (when ordering printer unit) |