Hioki 9694 Current Sensor
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
Discover the possibilities
More information
Description
Hioki 9694 Current Sensor
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9694 is 5A AC clamp sensors with voltage output for measuring load current. CAT III 300V
Key Features
• For inverter devices or commercial power lines
• For measuring the secondary side of 5A CTs
• Fits in narrow spaces due to compact design
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated measurement current | 5 A AC |
---|---|
Max. measurement current | Continuous 50 A (45 to 66 Hz) |
Output rate | 10 mV AC/ A |
Amplitude accuracy (45 to 66 Hz) | ±0.3 % rdg. ±0.02 % f.s. |
Phase accuracy | ±2° (45 Hz to 5 kHz) |
Amplitude frequency characteristics | Within ±1% at 40 Hz - 5 kHz (deviation from amplitude accuracy) |
Max. rated voltage to earth | 300 V AC rms or less |
Measurable conductor diameter | φ 15 mm (0.59 in) or less |
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
Dustproofness and waterproofness | N/A |
Dimensions and mass | 46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm (0.83 in)D, 230 g (8.1 oz)Cord length 3 m (9.84 ft), Output terminal: BNC |
Documents
Options
Video
Hioki 9694 Current Sensor
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9694 is 5A AC clamp sensors with voltage output for measuring load current. CAT III 300V
Key Features
• For inverter devices or commercial power lines
• For measuring the secondary side of 5A CTs
• Fits in narrow spaces due to compact design
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated measurement current | 5 A AC |
---|---|
Max. measurement current | Continuous 50 A (45 to 66 Hz) |
Output rate | 10 mV AC/ A |
Amplitude accuracy (45 to 66 Hz) | ±0.3 % rdg. ±0.02 % f.s. |
Phase accuracy | ±2° (45 Hz to 5 kHz) |
Amplitude frequency characteristics | Within ±1% at 40 Hz - 5 kHz (deviation from amplitude accuracy) |
Max. rated voltage to earth | 300 V AC rms or less |
Measurable conductor diameter | φ 15 mm (0.59 in) or less |
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
Dustproofness and waterproofness | N/A |
Dimensions and mass | 46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm (0.83 in)D, 230 g (8.1 oz)Cord length 3 m (9.84 ft), Output terminal: BNC |