Hioki 9669 Current Sensor
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9669 is 1000A AC clamp sensors with voltage output for measuring load current. CAT III 600V
Key Features
• For inverter devices or commercial power lines
• Measure up to 1000 A
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated measurement current | 1000 A AC |
---|---|
Max. measurement current | Continuous 1000 A (45 to 66 Hz) |
Output rate | 0.5 mV AC/ A |
Amplitude accuracy (45 to 66 Hz) | ±1.0% rdg. ±0.01% f.s. |
Phase accuracy | ±1° (45 Hz to 5 kHz) |
Amplitude frequency characteristics | Within ±2% at 40 Hz - 5 kHz (deviation from accuracy) |
Max. rated voltage to earth | 600 V AC rms or less |
Measurable conductor diameter | φ 55 mm (2.17 in) or less80 × 20 mm, Buss bars |
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
Dustproofness and waterproofness | N/A |
Dimensions and mass | 99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 mm (1.65 in)D, 590 g (20.8 oz)Cord length 3 m (9.84 ft), Output terminal: BNC |
Documents
Options
Video
Hioki 9669 Current Sensor
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9669 is 1000A AC clamp sensors with voltage output for measuring load current. CAT III 600V
Key Features
• For inverter devices or commercial power lines
• Measure up to 1000 A
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated measurement current | 1000 A AC |
---|---|
Max. measurement current | Continuous 1000 A (45 to 66 Hz) |
Output rate | 0.5 mV AC/ A |
Amplitude accuracy (45 to 66 Hz) | ±1.0% rdg. ±0.01% f.s. |
Phase accuracy | ±1° (45 Hz to 5 kHz) |
Amplitude frequency characteristics | Within ±2% at 40 Hz - 5 kHz (deviation from accuracy) |
Max. rated voltage to earth | 600 V AC rms or less |
Measurable conductor diameter | φ 55 mm (2.17 in) or less80 × 20 mm, Buss bars |
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
Dustproofness and waterproofness | N/A |
Dimensions and mass | 99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 mm (1.65 in)D, 590 g (20.8 oz)Cord length 3 m (9.84 ft), Output terminal: BNC |