Hioki 9660 Current Sensor
2.237,50 incl. VAT
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9660 is 100A AC clamp sensors with voltage output for measuring load current. CAT III 300V
Discover the possibilities
More information
Description
Hioki 9660 Current Sensor
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9660 is 100A AC clamp sensors with voltage output for measuring load current. CAT III 300V
Key Features
• For inverter devices or commercial power lines
• Fits in narrow spaces due to compact design
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated measurement current | 100 A AC |
---|---|
Max. measurement current | Continuous 130 A (45 to 66 Hz) |
Output rate | 1 mV AC/ A |
Amplitude accuracy (45 to 66 Hz) | ±0.3 % rdg. ±0.02 % f.s. |
Phase accuracy | ±1° (45 Hz to 5 kHz) |
Amplitude frequency characteristics | Within ±1% at 40 Hz - 5 kHz (deviation from amplitude accuracy) |
Max. rated voltage to earth | 300 V AC rms or less |
Measurable conductor diameter | φ 15 mm (0.59 in) or less |
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
Dustproofness and waterproofness | N/A |
Dimensions and mass | 46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm (0.83 in)D, 230 g (8.1 oz)Cord length 3 m (9.84 ft), Output terminal: BNC |
Documents
Options
Video
Hioki 9660 Current Sensor
Hioki current sensors are best-in-class devices for use with power meters, and PQAs. The 9660 is 100A AC clamp sensors with voltage output for measuring load current. CAT III 300V
Key Features
• For inverter devices or commercial power lines
• Fits in narrow spaces due to compact design
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated measurement current | 100 A AC |
---|---|
Max. measurement current | Continuous 130 A (45 to 66 Hz) |
Output rate | 1 mV AC/ A |
Amplitude accuracy (45 to 66 Hz) | ±0.3 % rdg. ±0.02 % f.s. |
Phase accuracy | ±1° (45 Hz to 5 kHz) |
Amplitude frequency characteristics | Within ±1% at 40 Hz - 5 kHz (deviation from amplitude accuracy) |
Max. rated voltage to earth | 300 V AC rms or less |
Measurable conductor diameter | φ 15 mm (0.59 in) or less |
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
Dustproofness and waterproofness | N/A |
Dimensions and mass | 46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm (0.83 in)D, 230 g (8.1 oz)Cord length 3 m (9.84 ft), Output terminal: BNC |