Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
- Test voltage up to 30 kV for air and contact discharge
- Color touch display
- Discharges up to 25 Hz
- 80 easy-to-change R/C-networks and tips
- Switchable Bleed-Off function
- Built-in activity log
- AC mains supply and DC supply
- Optional battery tested to 30,000 pulses @30 kV
Discover the possibilities
More information
Description
EM TEST esd NX30 ESD Generator
The EM Test esd NX30 ESD Generator generates ESD pulses above EN/IEC 61000-4-2 test levelsElectrostatic discharges either from a human body to any other part or between two different objects can cause persistent disturbances or even destruction to sensitive electronics or controls.
esd NX30 is an ESD tester to simulate ESD pulses at higher voltages up to 30 kV in both air and contact discharge mode. It therefore satisifiers requirements exceeding the EN/IEC 61000-4-2 test levels and complies to automotive test applications.
Specifications
AVAILABLE esd NX30-MODELS | |
esd NX30 | - high voltage base unit with - built-in battery pack - discharge gun - Interface, Interlock - 150 pF/330 Ohm discharge network - self calibration - carrying case |
esd NX30.1 | - high voltage base unit - discharge gun |
esd NX30-AUTO | - ESD NX30 Unit - ISO 10605 discharge networks - 150 pF/2000 ohm - 330 pF/2000 ohm - 330 pF/330 ohm - 150 pF/330 Ohm |
Test Level | |
Contact discharge | 200 V - 30,000 V ± 5 % |
Air discharge | 200 V - 30,000 V ± 5 % |
Resolution | 100 V steps |
Holding time (AD) | More than 5 s |
Output | |
Contact Discharge Pulse | per EN/IEC 61000-4-2 Ed.2, per ISO 10605 Ed.2 150 pF/330 ohm |
Rise time | 0.8 ns +/- 25%, 0.7 ns - 1 ns |
First peak current value | 7.5 A ± 15 % @2 kV 15 A ± 15 % @4 kV 22.5 A ± 15 % @6 kV 30 A ± 15 % @8 kV |
Current value at 30ns | 4.0 A ± 30 % @2 kV 8.0 A ± 30 % @4 kV 12.0 A ± 30 % @6 kV 16.0 A ± 30 % @8 kV |
Current value at 60ns | 2.0 A ± 30 % @2 kV 4.0 A ± 30 % @4 kV 6.0 A ± 30 % @6kV 8.0 A ± 30 % @8 kV |
Trigger | |
Single pulse | Release of a single pulse |
Multiple pulses | Continuous air discharge up to 25 Hz, contact discharges up to 20 Hz, random discharges |
Counter | 0 - 9,999 for discharge pre-selection |
esd NX30 | |
HV power supply | Up to 30 kV DC |
Built-in Battery | Approx. 30 k discharges; Battery is automatically recharged when connected to AC mains supply |
Interface | Optical and interlock |
Self calibration | After power on, by user any time |
esd NX30.1 | |
HV power supply | Up to 30 kV DC |
Self calibration | after power on |
Discharge Gun | |
Controls | Color touch display |
Test level | 200 V to 30,000 V |
Polarity | Positive, negative, alternating, selectable |
Discharge mode | Air or Contact discharge, selectable |
Discharge tip | Point and ball type |
Documents
EM TEST esd NX30 ESD Generator
EM Test esd NX30 DatasheetOptions
Video
EM TEST esd NX30 ESD Generator
EM TEST esd NX30 ESD Generator
The EM Test esd NX30 ESD Generator generates ESD pulses above EN/IEC 61000-4-2 test levelsElectrostatic discharges either from a human body to any other part or between two different objects can cause persistent disturbances or even destruction to sensitive electronics or controls.
esd NX30 is an ESD tester to simulate ESD pulses at higher voltages up to 30 kV in both air and contact discharge mode. It therefore satisifiers requirements exceeding the EN/IEC 61000-4-2 test levels and complies to automotive test applications.
Specifications
AVAILABLE esd NX30-MODELS | |
esd NX30 | - high voltage base unit with - built-in battery pack - discharge gun - Interface, Interlock - 150 pF/330 Ohm discharge network - self calibration - carrying case |
esd NX30.1 | - high voltage base unit - discharge gun |
esd NX30-AUTO | - ESD NX30 Unit - ISO 10605 discharge networks - 150 pF/2000 ohm - 330 pF/2000 ohm - 330 pF/330 ohm - 150 pF/330 Ohm |
Test Level | |
Contact discharge | 200 V - 30,000 V ± 5 % |
Air discharge | 200 V - 30,000 V ± 5 % |
Resolution | 100 V steps |
Holding time (AD) | More than 5 s |
Output | |
Contact Discharge Pulse | per EN/IEC 61000-4-2 Ed.2, per ISO 10605 Ed.2 150 pF/330 ohm |
Rise time | 0.8 ns +/- 25%, 0.7 ns - 1 ns |
First peak current value | 7.5 A ± 15 % @2 kV 15 A ± 15 % @4 kV 22.5 A ± 15 % @6 kV 30 A ± 15 % @8 kV |
Current value at 30ns | 4.0 A ± 30 % @2 kV 8.0 A ± 30 % @4 kV 12.0 A ± 30 % @6 kV 16.0 A ± 30 % @8 kV |
Current value at 60ns | 2.0 A ± 30 % @2 kV 4.0 A ± 30 % @4 kV 6.0 A ± 30 % @6kV 8.0 A ± 30 % @8 kV |
Trigger | |
Single pulse | Release of a single pulse |
Multiple pulses | Continuous air discharge up to 25 Hz, contact discharges up to 20 Hz, random discharges |
Counter | 0 - 9,999 for discharge pre-selection |
esd NX30 | |
HV power supply | Up to 30 kV DC |
Built-in Battery | Approx. 30 k discharges; Battery is automatically recharged when connected to AC mains supply |
Interface | Optical and interlock |
Self calibration | After power on, by user any time |
esd NX30.1 | |
HV power supply | Up to 30 kV DC |
Self calibration | after power on |
Discharge Gun | |
Controls | Color touch display |
Test level | 200 V to 30,000 V |
Polarity | Positive, negative, alternating, selectable |
Discharge mode | Air or Contact discharge, selectable |
Discharge tip | Point and ball type |