TESEQ NSG 3040A-Series Multifunction Generator Systems
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
Multifunction Generator Systems - The Smart 4.8 kV Solution For CE Applications
- One box solution system
- Surge voltage to 4.8 kV
- EFT/Burst to 4.8 kV / 1 MHz
- PQT to 16 A / 300 VAC & DC
- Easy to use 7“ color touch screen
- Parameters can be changed while test is running
- Wide range of optional test accessories
Discover the possibilities
More information
Description
TESEQ NSG 3040A-Series Multifunction Generator Systems
Teseq’s new NSG 3040A is an easy-to-use multifunction generator that simulates electromagnetic
interference effects for immunity testing in conformity with international, national and manufacturers’ standards including the latest IEC/EN standards. The NSG 3040A system is designed to fulfill conducted EMC test requirements for CE mark testing, which generally include combination wave surge, Electrical Fast Transient (EFT) pulses and Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a much broader range of applications.
Featuring an innovative, modular design, the NSG 3040A is a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories.
Using state-of-the-art components, the self-contained modules set new standards with respect to switching and phase accuracy and exceed the existing standards’ requirements.
A 7” touch panel display with superb contrast and color makes controlling the NSG 3040A easy. For fast and efficient data entry, input devices include an integrated keyboard and a thumbwheel with additional keys for sensitivity adjustment. To achieve quick, reliable results in a development environment a standardized test can be initiated with just a few “clicks” using the integrated Test Assistance (TA) function.
Convenient touch input buttons make each parameter’s value highly visible and allow the user to quickly select and modify all settings. A stylus is not necessary, and ramp functions can be programmed quickly and easily. Multi-step test procedures can be created and their sequence or parameter values can be changed easily.
With expert mode users can make manual parameter changes using the thumbwheel while a test is under way, providing an effective and fast method for identifying critical threshold values.
The NSG 3040A has an Ethernet port for external PC control. The Windows-based control software simplifies test programming and compilation of complex test sequences with various types of tests.
Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests.
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
Parameter | Value |
---|---|
Pulse voltage (open circuit) | ±200 V to 4.8 kV (in 1 V steps) |
Pulse current (short circuit) | ±100 A to 2.4 kA |
Impedance | 2/12 Ω |
Polarity | positive / negative / alternate |
Pulse repetition | 10 s, up to 9'999 s (in 1 s steps) |
Test duration | 1 to 99'999 pulses, continuous |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Coupling | IEC (external / internal) |
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Parameter | Value |
---|---|
Pulse amplitude | ±200 V to 4.8 kV (in 1 V steps) - open circuit ±100 V to 2.4 kV (50 Ω matching system) |
Burst frequency | 100 Hz to 1000 kHz |
Polarity | positive / negative / alternate |
Repetition time | 10 ms to 9'999 s |
Burst duration | 10 μs to 9'999 s, single pulse |
Test duration | 1 s to 9'999 s, 1 min to 1600 min, endless |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Coupling | external / internal |
Dips, Interrupts & Variations
Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
Parameter | Value |
---|---|
Dips, Interrupts & Variations | From EUT voltage input to 0 V, 0% |
Uvar with optional variac | depending on model (VAR 3005A) |
Uvar with step transformer | 0, 40, 70, 80% (INA 650x) |
Peak inrush current capability | >500 A (at 230 V) |
Switching times | 1 to 5 μs (100 Ω load) |
Event time (T-Event) | 20 µs to 9'999 s, 0.5 to 9'999 cycles |
Repetition time | 10 ms to 9'999 s, 1 to 9'999 s |
Test duration | 1 to 99’999 events, continuous |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Variation test (with VAR 3005A only)
conforms to IEC/EN 61000-4-11
Parameter | Value |
---|---|
Uvar with optional variac | up to approx. 265 V (in 1 V steps) or up to 115% Uin (in 1% steps) |
Decreasing time Td | 1 ms to 9.999 s, 0.5 to 9999 cycles, abrupt |
UTime at reduced voltage Ts | 1 ms to 9.999 s, 0.5 to 9999 cycles |
Increasing time Ti | 1 ms to 9.999 s, 0.5 to 9999 cycles |
Repetition time | 1 to 5 μs (100 Ω load) |
Events | 1 to 99’999 |
Pulsed magnetic field in conjunction with 702A
conforms to IEC/EN 61000-4-9
Parameter | Value |
---|---|
Field | 100 to 1200 A/m |
Polarity | positive / negative / alternate |
Repetition time | 10 s to 9999s (in 1 s steps) |
Impedance | 2 Ω |
Coil / impedance factor | 0.01 to 100.00 |
Test duration | 1 to 9’999 pulses, endless |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Power magnetic field in conjunction with MFT 30 or MFO 6501 and MFC 30 & MFC 300
conforms to IEC/EN 61000-4-8
Parameter | Value |
---|---|
Field | 1 to max. 40 A/m |
Frequency | 50 or 60 Hz |
Coil factor | 0.01 to 100 |
Test duration | 1 s to 99’999 s, endless |
Documents
TESEQ NSG 3040A-Series Multifunction Generator Systems
NSG-3040A-seriesOptions
TESEQ NSG 3040A-Series Multifunction Generator Systems
NSG 3040A-IEC
NSG 3040A-EFT-CWS
NSG 3040A-CWS
NSG 3040A-DDV
NSG 3040A-EFT
Video
TESEQ NSG 3040A-Series Multifunction Generator Systems
Teseq’s new NSG 3040A is an easy-to-use multifunction generator that simulates electromagnetic
interference effects for immunity testing in conformity with international, national and manufacturers’ standards including the latest IEC/EN standards. The NSG 3040A system is designed to fulfill conducted EMC test requirements for CE mark testing, which generally include combination wave surge, Electrical Fast Transient (EFT) pulses and Power Quality Testing (PQT). Extensive expansion capabilities enable the system to be configured for a much broader range of applications.
Featuring an innovative, modular design, the NSG 3040A is a versatile system that can be configured for basic testing needs and expanded to meet the needs of sophisticated test laboratories.
Using state-of-the-art components, the self-contained modules set new standards with respect to switching and phase accuracy and exceed the existing standards’ requirements.
A 7” touch panel display with superb contrast and color makes controlling the NSG 3040A easy. For fast and efficient data entry, input devices include an integrated keyboard and a thumbwheel with additional keys for sensitivity adjustment. To achieve quick, reliable results in a development environment a standardized test can be initiated with just a few “clicks” using the integrated Test Assistance (TA) function.
Convenient touch input buttons make each parameter’s value highly visible and allow the user to quickly select and modify all settings. A stylus is not necessary, and ramp functions can be programmed quickly and easily. Multi-step test procedures can be created and their sequence or parameter values can be changed easily.
With expert mode users can make manual parameter changes using the thumbwheel while a test is under way, providing an effective and fast method for identifying critical threshold values.
The NSG 3040A has an Ethernet port for external PC control. The Windows-based control software simplifies test programming and compilation of complex test sequences with various types of tests.
Test reports can be generated during the test operation, allowing the operator to enter observations as the test progresses and increasing the efficiency of long-term tests.
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
Parameter | Value |
---|---|
Pulse voltage (open circuit) | ±200 V to 4.8 kV (in 1 V steps) |
Pulse current (short circuit) | ±100 A to 2.4 kA |
Impedance | 2/12 Ω |
Polarity | positive / negative / alternate |
Pulse repetition | 10 s, up to 9'999 s (in 1 s steps) |
Test duration | 1 to 99'999 pulses, continuous |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Coupling | IEC (external / internal) |
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Parameter | Value |
---|---|
Pulse amplitude | ±200 V to 4.8 kV (in 1 V steps) - open circuit ±100 V to 2.4 kV (50 Ω matching system) |
Burst frequency | 100 Hz to 1000 kHz |
Polarity | positive / negative / alternate |
Repetition time | 10 ms to 9'999 s |
Burst duration | 10 μs to 9'999 s, single pulse |
Test duration | 1 s to 9'999 s, 1 min to 1600 min, endless |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Coupling | external / internal |
Dips, Interrupts & Variations
Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
Parameter | Value |
---|---|
Dips, Interrupts & Variations | From EUT voltage input to 0 V, 0% |
Uvar with optional variac | depending on model (VAR 3005A) |
Uvar with step transformer | 0, 40, 70, 80% (INA 650x) |
Peak inrush current capability | >500 A (at 230 V) |
Switching times | 1 to 5 μs (100 Ω load) |
Event time (T-Event) | 20 µs to 9'999 s, 0.5 to 9'999 cycles |
Repetition time | 10 ms to 9'999 s, 1 to 9'999 s |
Test duration | 1 to 99’999 events, continuous |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Variation test (with VAR 3005A only)
conforms to IEC/EN 61000-4-11
Parameter | Value |
---|---|
Uvar with optional variac | up to approx. 265 V (in 1 V steps) or up to 115% Uin (in 1% steps) |
Decreasing time Td | 1 ms to 9.999 s, 0.5 to 9999 cycles, abrupt |
UTime at reduced voltage Ts | 1 ms to 9.999 s, 0.5 to 9999 cycles |
Increasing time Ti | 1 ms to 9.999 s, 0.5 to 9999 cycles |
Repetition time | 1 to 5 μs (100 Ω load) |
Events | 1 to 99’999 |
Pulsed magnetic field in conjunction with 702A
conforms to IEC/EN 61000-4-9
Parameter | Value |
---|---|
Field | 100 to 1200 A/m |
Polarity | positive / negative / alternate |
Repetition time | 10 s to 9999s (in 1 s steps) |
Impedance | 2 Ω |
Coil / impedance factor | 0.01 to 100.00 |
Test duration | 1 to 9’999 pulses, endless |
Phase synchronization | asynchronous, synchronous 0 to 359º (in 1º steps) |
Power magnetic field in conjunction with MFT 30 or MFO 6501 and MFC 30 & MFC 300
conforms to IEC/EN 61000-4-8
Parameter | Value |
---|---|
Field | 1 to max. 40 A/m |
Frequency | 50 or 60 Hz |
Coil factor | 0.01 to 100 |
Test duration | 1 s to 99’999 s, endless |
TESEQ NSG 3040A-Series Multifunction Generator Systems
NSG-3040A-seriesTESEQ NSG 3040A-Series Multifunction Generator Systems
NSG 3040A-IEC
NSG 3040A-EFT-CWS
NSG 3040A-CWS
NSG 3040A-DDV
NSG 3040A-EFT