Hioki MR8902 Voltage/Temp Unit
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
Measure minute voltage or temperature waveform by 16 bit resolution, isolated input
Discover the possibilities
More information
Description
Hioki MR8902 Voltage/Temp Unit
Functions | No. of channels: 15, for voltage/temperature measurement (selectable for each channels) |
---|---|
Input connectors | Voltage/thermocouple input: push button terminalRecommended wire diameter: single-wire φ 0.32 mm to φ 0.65 mm, stranded wire 0.08 to 0.32 mm2 (conductor wire diameter min. φ 0.12 mm), AWG 28 to 22Input resistance: 1 MΩMax. rated voltage to earth: 100 V AC, DC (with input isolated from the main unit, the max. voltage that can be applied between input channel and chassis and between input channels without damage) |
Voltage measurement ranges | 500 μV to 5 V/div, 9 ranges, full scale: 20 division * The AC instantaneous voltage waveform cannot be measured due to the slow sampling speed.Resolution: 1/1000 of measurement range (using 16-bit A/D converter)Accuracy: ±0.1 % f.s. (with digital filter ON, Zero position accuracy included) |
Temperature measurement range | Reference junction compensation: Internal/ External (selectable)Thermocouple broken-wire detection: ON/OFF (selection applies to entire unit)Thermocouple type: K, J, E, T, N, R, S, B, WRe5-26* For thermocouple measurement ranges, resolution, and accuracy, refer to the specifications table below |
Digital filter | 50 Hz, 60 Hz, or OFF |
Data refresh rate | 10 ms (with filter OFF, burn-out detection OFF)20 ms (with filter OFF, burn-out detection ON)500 ms (with filter ON, data refresh rate: Fast)2 s (with filter ON, data refresh rate: Normal) |
Max. allowable input | 100 V DC (the max. voltage that can be applied across input pins without damage) |
Dimensions and mass | 119.5mm (4.70 in)W × 18.8mm (0.74 in)H × 184.8mm (7.28 in)D, 190 g (6.7 oz) |
Accessories | Ferrite clamp ×2 |
Documents
Options
Video
Hioki MR8902 Voltage/Temp Unit
Functions | No. of channels: 15, for voltage/temperature measurement (selectable for each channels) |
---|---|
Input connectors | Voltage/thermocouple input: push button terminalRecommended wire diameter: single-wire φ 0.32 mm to φ 0.65 mm, stranded wire 0.08 to 0.32 mm2 (conductor wire diameter min. φ 0.12 mm), AWG 28 to 22Input resistance: 1 MΩMax. rated voltage to earth: 100 V AC, DC (with input isolated from the main unit, the max. voltage that can be applied between input channel and chassis and between input channels without damage) |
Voltage measurement ranges | 500 μV to 5 V/div, 9 ranges, full scale: 20 division * The AC instantaneous voltage waveform cannot be measured due to the slow sampling speed.Resolution: 1/1000 of measurement range (using 16-bit A/D converter)Accuracy: ±0.1 % f.s. (with digital filter ON, Zero position accuracy included) |
Temperature measurement range | Reference junction compensation: Internal/ External (selectable)Thermocouple broken-wire detection: ON/OFF (selection applies to entire unit)Thermocouple type: K, J, E, T, N, R, S, B, WRe5-26* For thermocouple measurement ranges, resolution, and accuracy, refer to the specifications table below |
Digital filter | 50 Hz, 60 Hz, or OFF |
Data refresh rate | 10 ms (with filter OFF, burn-out detection OFF)20 ms (with filter OFF, burn-out detection ON)500 ms (with filter ON, data refresh rate: Fast)2 s (with filter ON, data refresh rate: Normal) |
Max. allowable input | 100 V DC (the max. voltage that can be applied across input pins without damage) |
Dimensions and mass | 119.5mm (4.70 in)W × 18.8mm (0.74 in)H × 184.8mm (7.28 in)D, 190 g (6.7 oz) |
Accessories | Ferrite clamp ×2 |