Hioki 9657 Current Sensor
Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk
Discover the possibilities
More information
Description
Hioki 9657 Current Sensor
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9657-10 is a voltage output clamp sensor for measuring leak current. The high-permeability magnetic material of the sensor’s core and magnetic shield enables high-precision measurement of very weak currents. CAT III 300V
Key Features
• For general purpose leak current testin
■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated primary current | AC 10 A (for leak current measurement, 50/60 Hz) |
---|---|
Max. allowable input (45-66 Hz) | Max. 30 A of continuous input |
Rated output current | AC 100 mV/A |
Amplitude accuracy (45-66 Hz) | ±1.0 % rdg. ±0.05 % f.s. |
Phase accuracy | ±3 ° (at 50 Hz or 60 Hz) |
Frequency characteristics | 40 Hz to 5 kHz: ± 3%\n(Add to amplitude accuracy) |
Max. rated voltage to earth | AC 300 V rms (Insulated conductor, CAT III) |
Core diameter | φ 40 mm (1.57 in) |
Dimensions and mass | 74 mm (2.91 in)W × 145 mm (5.71 in)H × 42 mm (1.65 in)D, 380 g (13.4 oz), Cord length: 3 m (9.84 ft) |
Accessories | Instruction manual ×1 |
Documents
Options
Video
Hioki 9657 Current Sensor
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9657-10 is a voltage output clamp sensor for measuring leak current. The high-permeability magnetic material of the sensor’s core and magnetic shield enables high-precision measurement of very weak currents. CAT III 300V
Key Features
• For general purpose leak current testin
■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Rated primary current | AC 10 A (for leak current measurement, 50/60 Hz) |
---|---|
Max. allowable input (45-66 Hz) | Max. 30 A of continuous input |
Rated output current | AC 100 mV/A |
Amplitude accuracy (45-66 Hz) | ±1.0 % rdg. ±0.05 % f.s. |
Phase accuracy | ±3 ° (at 50 Hz or 60 Hz) |
Frequency characteristics | 40 Hz to 5 kHz: ± 3%\n(Add to amplitude accuracy) |
Max. rated voltage to earth | AC 300 V rms (Insulated conductor, CAT III) |
Core diameter | φ 40 mm (1.57 in) |
Dimensions and mass | 74 mm (2.91 in)W × 145 mm (5.71 in)H × 42 mm (1.65 in)D, 380 g (13.4 oz), Cord length: 3 m (9.84 ft) |
Accessories | Instruction manual ×1 |