{"title":"CDN's (Coupling \/ Decoupling Networks)","description":"\u003cspan style=\"font-size: 0.875rem;\"\u003eThe AMETEK CTS wide range of coupling\/decoupling networks (CDNs) are precisely designed and engineered to meet the design and performance requirements outlined in IEC\/EN 61000-4-6.\u003c\/span\u003e\u003cbr\u003e","products":[{"product_id":"em-test-cni508n2","title":"EM TEST CNI508N2 Coupling\/decoupling","description":"CNI508N2 Coupling\/decoupling assembly for unshielded and shielded high-speed communication lines up to 1GBit\/s\n\u003cul\u003e\n \t\u003cli\u003eCoupling to unshielded and shielded lines with up to 4 pairs\u003c\/li\u003e\n \t\u003cli\u003eData transfer up to 1,000MBit\/s\u003c\/li\u003e\n \t\u003cli\u003eSurge test voltage up to 3kV (1.2\/50us)\u003c\/li\u003e\n \t\u003cli\u003eBurst test voltage up to 4kV (5\/50ns)\u003c\/li\u003e\n \t\u003cli\u003eRingwave test voltage up to 4kV (0.5us\/100kHz)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EM TEST","offers":[{"title":"Default Title","offer_id":48309440872781,"sku":"CNI508N2","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/CNI508N2-1.jpg?v=1701164894"},{"product_id":"cdn-m-series","title":"CDN M Series","description":"Coupling networks designed for IEC\/EN 61000-4-6\n\nM series for mains applications\n\nModels with 4 mm banana sockets\n\nModels with frequency range 10 kHz to 80 MHz, 150 kHz to 230 MHz or up to 300 MHz\n\nVery efficient coupling also for 100 Amps CDNs","brand":"Teseq","offers":[{"title":"Default Title","offer_id":48310254371149,"sku":"CDN M Series","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/CDN_M232.png?v=1701176569"},{"product_id":"demo-cdn-m532","title":"DEMO TESEQ CDN M532 Coupling network","description":"Coupling networks designed for IEC\/EN 61000-4-6\n\nM series for mains applications\n\nModels with 4 mm banana sockets\n\nModels with frequency range 10 kHz to 80 MHz, 150 kHz to 230 MHz or up to 300 MHz\n\nVery efficient coupling also for 100 Amps CDNs","brand":"Teseq","offers":[{"title":"Default Title","offer_id":48310254633293,"sku":"CDN M532","price":9275.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/CDN_M232_a0bd454f-f722-4b49-9d22-c2abbda97cac.png?v=1715580837"},{"product_id":"teseq-cdn-s900-10-d-sub","title":"Teseq CDN S900-10 D-Sub","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range: \u003c\/strong\u003e10 kHz to 80 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector EUT Port: \u003c\/strong\u003eD-Sub 9 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector AE Port:\u003c\/strong\u003e D-Sub 9 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Parameters: \u003c\/strong\u003e9 screened lines¹\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Configuration:\u003c\/strong\u003e Data line up to Number of wires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltage, 2 sec.:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Impedance (EUT Port):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e10 kHz to 24 MHz: 150 Ω ±20 Ω \u003c\/li\u003e\n\u003cli\u003e24 MHz to 80 MHz: 150 Ω +60 Ω\/-45 Ω \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootnote:\u003c\/strong\u003e ¹: Compatible to RS 232 application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Teseq","offers":[{"title":"Default Title","offer_id":54679442653517,"sku":"242478","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/teseq-teseq-cdn-s250-d-sub-coupling-decoupling-networks-9833818.webp?v=1792066397"},{"product_id":"teseq-cdn-s250-10-d-sub","title":"Teseq CDN S250-10 D-Sub","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range: \u003c\/strong\u003e10 kHz to 80 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector EUT Port: \u003c\/strong\u003eD-Sub 25 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector AE Port:\u003c\/strong\u003e D-Sub 25 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Parameters: \u003c\/strong\u003e25 screened lines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Configuration:\u003c\/strong\u003e Data line up to Number of wires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltage, 2 sec.:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Impedance (EUT Port):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e10 kHz to 24 MHz: 150 Ω ±20 Ω \u003c\/li\u003e\n\u003cli\u003e24 MHz to 80 MHz: 150 Ω +60 Ω\/-45 Ω \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootnote:\u003c\/strong\u003e ¹: Compatible to RS 232 application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Teseq","offers":[{"title":"Default Title","offer_id":54679615177037,"sku":"242480","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/teseq-teseq-cdn-s250-d-sub-coupling-decoupling-networks-9833818.webp?v=1792066397"},{"product_id":"teseq-cdn-s900-d-sub","title":"Teseq CDN S900 D-Sub","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 150 kHz to 230 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector EUT Port: \u003c\/strong\u003eD-Sub 9 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector AE Port:\u003c\/strong\u003e D-Sub 9 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Parameters: \u003c\/strong\u003e9 screened lines¹\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Configuration:\u003c\/strong\u003e Data line up to Number of wires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltage, 2 sec.:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Impedance (EUT Port):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e150 kHz to 24 MHz: 150 Ω ±20 Ω\u003c\/li\u003e\n\u003cli\u003e24 MHz to 80 MHz: 150 Ω +60 Ω\/-45 Ω\u003c\/li\u003e\n\u003cli\u003e80 MHz to 230 MHz: 150 Ω ±60 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootnote:\u003c\/strong\u003e ¹: Compatible to RS 232 application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Teseq","offers":[{"title":"Default Title","offer_id":54679639556429,"sku":"231007","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/teseq-teseq-cdn-s250-d-sub-coupling-decoupling-networks-9833818.webp?v=1792066397"},{"product_id":"teseq-cdn-s900m-d-sub","title":"Teseq CDN S900m D-Sub","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 150 kHz to 230 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector EUT Port: \u003c\/strong\u003eD-Sub 9 pins (m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector AE Port:\u003c\/strong\u003e D-Sub 9 pins (m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Parameters: \u003c\/strong\u003e9 screened lines¹\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Configuration:\u003c\/strong\u003e Data line up to Number of wires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltage, 2 sec.:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Impedance (EUT Port):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e150 kHz to 24 MHz: 150 Ω ±20 Ω\u003c\/li\u003e\n\u003cli\u003e24 MHz to 80 MHz: 150 Ω +60 Ω\/-45 Ω\u003c\/li\u003e\n\u003cli\u003e80 MHz to 230 MHz: 150 Ω ±60 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootnote:\u003c\/strong\u003e ¹: Compatible to RS 232 application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Teseq","offers":[{"title":"Default Title","offer_id":54679657546061,"sku":"256766","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/teseq-teseq-cdn-s250-d-sub-coupling-decoupling-networks-9833818.webp?v=1792066397"},{"product_id":"teseq-cdn-s150-d-sub","title":"Teseq CDN S150 D-Sub","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 150 kHz to 230 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector EUT Port: \u003c\/strong\u003eD-Sub 15 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector AE Port:\u003c\/strong\u003e D-Sub 15 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Parameters: \u003c\/strong\u003e15 screened lines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Configuration:\u003c\/strong\u003e Data line up to Number of wires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltage, 2 sec.:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Impedance (EUT Port):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e150 kHz to 24 MHz: 150 Ω ±20 Ω\u003c\/li\u003e\n\u003cli\u003e24 MHz to 80 MHz: 150 Ω +60 Ω\/-45 Ω\u003c\/li\u003e\n\u003cli\u003e80 MHz to 230 MHz: 150 Ω ±60 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootnote:\u003c\/strong\u003e ¹: Compatible to RS 232 application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Teseq","offers":[{"title":"Default Title","offer_id":54679669506381,"sku":"231008","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/teseq-teseq-cdn-s250-d-sub-coupling-decoupling-networks-9833818.webp?v=1792066397"},{"product_id":"teseq-cdn-s250-d-sub","title":"Teseq CDN S250 D-Sub","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 150 kHz to 230 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector EUT Port: \u003c\/strong\u003eD-Sub 25 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector AE Port:\u003c\/strong\u003e D-Sub 25 pins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Parameters: \u003c\/strong\u003e25 screened lines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Configuration:\u003c\/strong\u003e Data line up to Number of wires\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC max. voltage (L-GND): \u003c\/strong\u003e150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Max:\u003c\/strong\u003e 250 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Voltage, 2 sec.:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Impedance (EUT Port):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e150 kHz to 24 MHz: 150 Ω ±20 Ω\u003c\/li\u003e\n\u003cli\u003e24 MHz to 80 MHz: 150 Ω +60 Ω\/-45 Ω\u003c\/li\u003e\n\u003cli\u003e80 MHz to 230 MHz: 150 Ω ±60 Ω\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFootnote:\u003c\/strong\u003e ¹: Compatible to RS 232 application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Teseq","offers":[{"title":"Default Title","offer_id":54679681368397,"sku":"231009","price":0.0,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/files\/teseq-teseq-cdn-s250-d-sub-coupling-decoupling-networks-9833818.webp?v=1792066397"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/9344\/9805\/collections\/CDN-S-Series.png?v=1701164040","url":"https:\/\/gomeasure.dk\/en-se\/collections\/cdn.oembed","provider":"GOmeasure.dk","version":"1.0","type":"link"}